Greener Journal of Chemical Science and Technology

Open Access

Kuru

Greener Journal of Chemical Science and Technology Vol. 1 (1), pp. 015-020, May 2014.

ISSN: 2384-6364  © 2013 Greener Journals

Research Paper

Manuscript Number: 012314057

 

Effect of Compression Ratio on LNG Exchanger for Single Mixed Refrigerant Plant

 

Kuru Tuka

 

Department of Chemical Engineering, University of Port Harcourt.

 

Email: tukakuru @ gmail .com

Abstract:

In liquefying natural gas using the single mixed refrigerant system, the compression ratio for the compressor used will largely determine the power requirement of the system, coefficient performance of the cycle, efficiency of the main cryogenic heat exchanger and size of the exchanger. The power requirement also determines the energy cost for liquefaction. Five cases were considered with compression ratios of 2.0, 3.0, 4.0, 5.0, and 6.0 for the single mixed refrigerant system. Different compression power requirement, UA, mean temperature difference and coefficient of performance were obtained. Plot of temperature versus heat flow for all five cases showed the performance of the exchanger in each of the cases.

Keywords: Compression ratio, heat exchanger, single mixed refrigerant, coefficient of performance.